BTW, this can be caused from a water hammer effect, running the pump and then shutting off flow suddenly, or the fitting could have been overtightened to begin with, 7 years ago, and age caused it to give way. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. . If none of those, it likely is an internal short across the wirings, or a bent shaft, which is the end of that motors life. Even if it looks good, it could be bad. Could be too much or too little sand, the filter should be about 2/3 full of sand. Check the wiring. Hi, I have a H250PED2. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). If so, you need stronger hose (or pipe), or add another suction pipe (and wall fitting). could be the motor, if the shaft has worn unevenly, or if there are grooves or rust on the shaft. Then, I tried plugged the pump into another power outlet and it still does not work. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). Hi There I have a Hayward Super Pump VS pump. Thoughts? Terrible storms 2 nights ago. Get Mountainside Fitness reviews, ratings, business hours, phone numbers, and directions. I tried -no way .then 3 very strong men all tried all of them had to put stress on the plumbing pipes to get the darn thing loosened at all ..what a NGHTMARE no we are not over tightening any suggestions? Additional causes for low water flow in your pump are debris build-up or dirty equipment. Theres not much room back there for wires, and if they get too close to other things. The print and bearings were replaced. K-1766 Taylor Salt Test Hi Josh, that sounds like the Display board, a circuit board that controls the display. What is the problem. Thanks! Hello, Just bought a house with a pool in January. Hi Tom, there is an o-ring that seals up the tank flange to the valve flange, its usually on the valve, when you remove the valve, might need replacement and/or a good cleaning and lubing. "@context": "https://schema.org/",
Any new postings here are unlikely to be seen or responded to by other members. Have a Hayward pump. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. The volute screws (around the impeller housing) do not need to be removed. Hard for me to say if the motor is shot, but it has sure had a rough life! I tried to prime the pump but it still doesnt kick over to cycle anything. "caption": "In The Swim Blog"
Next step would be to remove the cover and put your leads on the terminal board, right where each wire connects. A TEST button that is popped? Is it plug and play? This is a black cylinder located in the back of the motor, at 9 oclock, which acts as a battery to give the motor extra juice to start. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. Please help! I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Products, Learn About Thank you Happens all the time to pool pumps, and the way to un-stick it is to do some disassembly in the rear of the motor, to get a wrench on the slotted rear of the motor shaft, and work the shaft back and forth for a minute, to break the rust seal, and get the shaft to turn again. It does sit in a low spot and has happened once before, but I do have a solution to prevent it from happening again. If the pond is located below the pool equipment, then the pump and filter and pipes will drain down to that level, once the drain plugs are removed. 3. clogged pump impeller or very dirty filter. Im not sure how the filters went bad being winterized, but they were way old. 5 Changed the seal Turned it off and now it makes the grinding noise and turns off itself. This week the motor If flame is sensed with the gas valve off the control will go into lockout. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Please help! larger hp motors, are not reversible. 3. slide pump backwards, out of the housing, remove diffuser and wear ring from impeller Do I need to clean filter? If you attached the cord, make sure that the wires are correctly attached to the terminal board, and the ground wire secure. Power is getting to the pump but the pump will not run?. Does it only do this when vacuuming, but otherwise runs fine? Pump is grounded. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. What should I check? I have an above ground 18,000gal poola Hayward SP1580X15 Power-Flo LX 1 1/2 HP pump purchased May 2017. When they fail, they often crack, bulge, leak or smell bad, but not always. Otherwise if not, you go in thru the back of the motor, remove the capacitor bracket to drop the cap out of the way, so you can slip a 7/16 wrench on the slotted back 1/2 of the shaft, and work it back and forth for 30 seconds to break the rust. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. If from the center of the lid around the stem, you can replace the two small stem o-rings, but sometimes the stem is worn down and needs replacement. the pop may have been the capacitor blowing, its a black cylinder located at 9 oclock in the rear of the motor. Still same though nothing being sucked through basket and minor trickle back out into pool. Use a Drain King to pressurize the pipe backwards, to remove such clogs. Power Pole Distribution Block, "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. Gas pressure is ok. Any ideas? Hi Mary, pump motors have a thermal overload switch, which trips when motor gets too hot, it resets itself when the motor cools down, and the motor should restart again on its own. Reconnect the pipes and test it out! Could be one of these. of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the We would like to show you a description here but the site wont allow us. If not those, it could also be a short in the motor windings, which would be a major failure, requiring a new motor. I have back washed the filter about 6 times in 1 month, and even soaked the filter (the DE fingers) in a cleaning solution and also soaked it in Muriatic Acid for about 30 minutes. Products, learn In particular, if the salt content of your pool water is too high, your metal screws, handrails, ladders, and covers will rust excessively. Also make sure that the pump has no air leaks from loose pipes, loose pump lid, low water level in pool For you Scott, the next step is to shut off power to pump and remove the Blue, Black and Red wires (page 4 owners manual) from the drive and check each motor lead to ground. Samsung Da29-00020b 3 Pack, Could this be my problem? When this has been corrected, shut the power down to the pump and rest it after 15 minutes. I cannot locate the model # on either but believe the filter is a c250. Can I replace this pump housing or do I need a new pump? Gasket Maker. Flip the switch opposite, and you should be all set. My diffuser does not tightly fit into my seal plate. Any ideas on how to fix this issue?? Hi Phil, hmmm, could be a breaker that is going bad they tend to wear out after 20 years or so, especially if they are used often, as a switch. The waste tube on my filter is filler while my pump is running. Maybe thats off. anyway I digress. Could be overheating make sure the pump has lots of air around the motor, no piles of mulch or dirt packed around the pump. Hi Damon, I would suspect the chattering sound to be a loose stationary switch and/or centrifugal switch on the motor, in the rear of the motor, remove the cover and look for something amiss. Which explains the clicking of the pump. I suspect a loose wire, or mis-wiring or other simple fix. If you can grab the bolt head underneath the pad with pliers, that could help, otherwise you can cut the bolts off using a reciprocating saw with a metal blade. Hi David, yes! An error was detected in the ignition control circuit board. I have a Hayward super pump 1HP. I have a humming noise when plugged in, but can seem to get the cover off. I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. It bubbles and their are very few ripples in the water. hayward blue essence troubleshootingpeel and stick tile 914665 hayward blue essence troubleshooting. hayward blue essence troubleshooting. Do you know what would cause this? Any ideas on troubleshooting this issue? Especially a drip from the clamp band or the threaded fitting on the outlet port of the pump, or a dripping shaft seal, or leaking housing. How do I get the lid tight enough? Pump is 29 years old so wouldnt surprise me if impeller is failing. Or, 2). Any advice?? Or could it be a dirty motor or ground wire that isnt connected well enough? I checked pool water supply and dont feel any water coming but my pump is still running but nothing is moving in pool. Replace cell or entire system Aquatrol RJ with GLX tcell 5, Cheap option for linking a second salt cell, Brand new AquaRite 900 Check Salt and Inspect Cell light, Aqua Rite SWG and Hayward T-15 salt cell - low salt and inspect cell continue to flash after reset, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. One of the tads were not in the slot. I had it replaced. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. Just put he new motor on and its still not working, sounds like power is being sent to the motor, but nothing. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. Overheating can be a short across the windings, or it can be other major faults within the motor. Is there a trick to moving it to 115? Also inspect other wires in the back, look for any pinched wires, or wires touching each other. Hi Heidi, it sounds like maybe the plumbing could be reversed? I basically removed my old pump and instalked the new one. Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. It could be a problem the other way around, AG pumps cannot lift water vertically, so are not used on inground pools. What are some items I should check assy A for on the bench so I can possibly repair it? So My pool pump is two speed and I have it set to run for 3 hours in low speed and 5 in high. Informacin detallada del sitio web y la empresa: cd77petanque.com Comit de seine et marne de ptanque Is this a pump problem, priming problem (filter, pipes losing water somewhere)? When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. 14mm Magnetic Spark Plug Socket, I have a t-15 cell. Nothin seems to be leaking anywhere. The new one is doing the same thing. I also tried it in a different place same outcome.What am I doing wrong? presto, all working good! Heat exchanger has to be getting too hot? check that everything is tight and aligned. Also, make sure you plug in the cell all the way. Please help. The pump acts like it wants to pump, but doesnt. The Tristar VS would be a good choice and easy to plumb, since its the same pump. Now Im getting small air bubbles when the speed is on low. I shut the pump down the other night and it will not run. Not sure power goes to the pump. I made sure the basket was seated properly and put grease on the o-ring on the cover and made sure it was tight. I can see the water trickling in to the filter after a while, and the output becomes very limited. You will need a new plug and a new outlet and maybe a new pump too (? Took out filters and it pumps perfect. Is this a new or older installation? Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. I even tried another new housing gasket and it still leaks. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. The unit works fine for approximately 4- 6 hours, then the Check Salt and Inspect Cell flashes (salt level on the unit reads 2600 ppm). "headline": "Hayward Pool Pump Troubleshooting",
However it doesnt turn on. Heaters often normally make such sounds, could also be debris laying on top of the burners. Or you can buy the bearings and seal, and with a set of bearing pullers you can replace your own. Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. Test to see if 120V (+/- 10%) is coming into the motor, on the two wire terminals. If very clogged, you can usually tell, because debris will float out and you can grab some of it with your fingertips or with pliers. Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. I have a Hayward super pump 1.5 hp. The Super Pump comes with all these labels that say it is set up and wired for 230. I have a Hayward pump with DE filter. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Is it rigid PVC or flexible pipe? We opened our pool a week ago and havent had a problem until today (May 23. easier. Air could also be entering the pump from the threaded pipe or union that is attached to the inlet port, which may also spray or drip when the pump shuts off. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. I will re-check all the wiring. If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. I believe you must have some type of switch, for code cant just wire it directly to the breaker. At no time does the power led turn on. Hello, Dear Davy, my pump was working two days ago then I switched it off. Just opening pool. After the pump and filter are fully drained, screw the plugs back in slightly to keep bugs out, but leave them loose so they will still drain, as needed. old. Then timer 2 comes on at 3:30 at 2250 rpms, but recently (last 3 mornings) when the second timer at the higher rpms comes on it does not prime and just runs without circulation water through the system. Just bought a new Hayward Perflex Series Extended Cycle Filtration Systems filter and cant get the motor to start. It wont stop leaking. I also have voltage (115 volts)on both sides of the fuse holder with no fuse installed. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. Hi, my Hayward pump is about 5 years old. Yes, pool heaters do have a minimum flow requirement. Using a circuit tester, I determined that the timer and the inline switch has power. Repair or replace any tripped breakers or blown fuses. "@type": "Organization",
Hi BRian, nothing special no make sure the outlet TEST button is not popped or tripped? 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted {
Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | We would like to show you a description here but the site wont allow us. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. At a total loss here, any suggestions would be greatly appreciated. It has been in operation since mid May without and incident before yesterday. If you have an electric motor repair shop in town, they may have it in stock, or order it online. Products, View Pumps need to be fairly air tight, and water tight to avoid drain down when they shut off. View Details Usfitnessfinder.com. To view these documents, you will need to download the free Acrobat Reader, which Whenever Ive seen that its from too much voltage, like connecting 220V to a motor wired for 110V. Is this normal or is there a malfunction? Follow disassembly/assembly procedures (pages 32 -37). Below is the troubleshooting guide for Hayward pool heater error codes. Inspect and clean your cell. the , . Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Sanitization, Learn About Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. It could also be just too much moisture on the motor terminals. Also you can test the outlet with another small plugin item, like a hair dryer or lamp. You should be able to lift up on the pump just slightly, to push something thin, 1/4 thick or less, beneath it. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
JavaScript is disabled. I have digital timer with pump wire going into termials that are screwed down. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. Hayward Super Pump, 1 Hp running on 240V, 3 yrs old Step 5: Measure your cells polarity to ensure they meet system parameters. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. I dont see that code listed. I never had this problem before. While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Could need cleaning. At this point, you can shut off power at the breaker, and pop the mechanism out of the box by depressing the tabs on the top, and inspect the gears and motor directly, for any insect problems, gecko tails (seen it!) If not, use an outlet tester or plug in a different appliance (light, hair dryer, fan) to see if the outlet has power. If regular loudness, its likely an air leak. Tough one, good luck! "height": "219",
Put it in the line at the pool, and as the pump begins to catch prime, crimp the hose and slowly pull out of the pipe. This year I have developed a leak under the pump housing I believe. 4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking They function as the starting battery for the motor, to help it get up to speed quickly. I have a new fiberglass pool and ever since I operate it the pump trips the breaker in most cases overnight hours between 2 timing sessions (pump not running). If flushing and draining does not help, it is time to open up the filter tank, remove the grid assy (or flex tube nest), and after cleaning very well with a hose, soak it in a DE filter cleaner solution (5-gal bucket works well for Perflex). IF the shaft spins freely, and your motor hums and trips the breaker, first check the wiring connections on the incoming wires, nice and tight, and no bare wire touching anything except the terminal connector. Make sure it is fully pushed into the panel, and the wires are tightly connected, which they likely are. MY PUMP STARTS TO PRIME THEN LOSES IT. When I tighten the impeller onto to the motor how tight should it be? Otherwise I would say the switch that changes from low to high may be stuck, from corrosion, insects or breakage. Does it mean the problem is on the pump itself ? I reset everything when I noticed the problem. If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. On attempting to open the pool, the motor started humming. Third possibility is the pipe size is too small, and your 90 gpm pump may be starved for water. How to Read and Adjust the Hayward Aqua Rite SCG Operational Values. If none found, inspect your valve settings, on the equipment pad, and make sure everything is normal, and the cleaner water flow is not being throttled or bypassed. With the information explained in this comprehensive troubleshooting guide, you can diagnose and repair your Hayward single speed or variable speed pool pump with ease! Is this a 2-speed pump, or variable speed pump? Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. We have our pump timers to shut off at noonmany times, but all the time, they run past the specified shut off time. Our troubleshooting guide will help you get it up and running in no time. regardless, i am replacing the electrical cord. . I have an Ecostar That has developed a pinhole spray leak at the top of where the pump housing oring sits between the pump and motor. 2. pump lid gasket or o-ring not lubed, or not positioned properly (superpump) When corrected, control will run blower for 5 s then automatically restart after 2 minutes. 14 x 28 inground, water clear. if it does not come back on, check switches, turn breaker all the way off and back on again. Spray off well, and soak in a 5-gal bucket, the entire Flex Tube Nest, for a number of hours, hose off again, soak for another few hours, hose off thoroughly, dunk in the pool a few times, then replace in the filter tank.