troubleshooting drummond shallow well pump

___________________________________________________. })(); Empire Pump Corporation, formerly known as Duncan Pump and established in 1946, is a commercial water well pump company in Phoenix Arizona that specializes in the installation and rehabilitation of water well pumps and systems no matter whether your system is residential, commercial, industrial, municipal, environmental, mines, or agricultural. The problem could be that there's no water in your well. and if there is power to the pump (on the pump side of the pressure switch that ought to be closed, calling for water) For further assistance, please contact us directly. 5 gal. Shake and listen for float to rattle. If you cant rock it or it feels top-heavy, its bad. . TC gasket missing in nosepiece, requires one on each end of filter (4-000-057). I woke up this morning to no water, i have a sump pump, what could be wrong. My well is full, I have pressure, wont pump water, when I touch the points together I have spark and the pump just hums, could this be the line is froze some where, or the motor is locked? Was using my hose the other day - pump shut off pressure dropped to zero. Is a good article but i still with my question because i did not find the answer . You can temporarily restore the surfaces to keep it going until you can buy a replacement switch. It could be set up as one large breaker of 30+ amps or a double circuit breaker with two lower amperages in tandem on the panelboard. A second possibility is an overheating well pump motor. As the pressure switch ages, these components can weaken and malfunction, at which time replacement is necessary. So then I pulled the well pump figuring it may be the check valve so I replace the check valve and reinstall the pump in the welland two weeks later it started doing the same thing again. 1. Turning the large nut changes the overall range higher or lower. Richie: Start by checking power, then the switch, wiring, and pump current draw. Remember, the water you use at this point should match the type of water you'll be drawing. Water is not being drawn, then it shuts off, went to my other well and it is doing the same. Check the pressure gauge to make sure it isn't stuck or damaged. If the well pump or control switch makes no noise at all, just hums or clicks, and when the water pump simply does not run these diagnostic questions may help track down and repair the trouble. Actuator button is stuck in the down position. Thank you. If your pump is not operating at all, move the switch relay contacts apart from each other and check to see if there is any pitting or burning on the contacts. Looking for more well maintenance tips? Today I noticed the pressure was not right then it finally had no pressure. No Water The most common problem in a household is turning on the water faucet, and no water comes out of the tap. I have a large amount of orange/brown mud that has oozed out of the rubber hose that connects between the tank and the top priming valve. Cut out hole or replace tubing (4-000-004). Download the Nanoject 3 (3-000-207) troubleshooting guide that offers solutions for common issues. To help ensure the Pump will start as required, check the Pump regularly with start-up tests. What can be the reason for the same pump to display under current - I have set this at 5.3 Amps, and to start functioning normally if the alternate pump is operated for a minute ( or less even ) ? It runs fine for 2-15 cycles, then will hum. Thanks for the quick reply! BobTake a look at the causes and cures found at WATER PUMP WON'T START. Anthony Here are some factors that can affect the life of your tank: If youre the type of person that likes to do your own home maintenance and repairs, this section is for you. Wayne Shallow well model . In the diagnostic table at WATER PUMP DIAGNOSTIC TABLE check out the section titled, Things to Check if the Well Pump Will Not Start. Write the product's serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). I had very little pressure, The pump is in about 80 feet of water.But the pump is about 20 years old too, See WATER PRESSURE PROBLEM DIAGNOSIS TABLE. Another possibility is that the switch contacts are burned. The well pump pulls or pushes depending on the type of pump the water from the well. Replace the pressure switch as soon as possible because this fix wont last long. Pump pressure control switch contact bouncing? Weekends: Emergency Service Calls Only. If loose, replace (4-000-053-A). Grove Electric, Typical Shallow Well One Line Jet Pump Installation [PDF], Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, . Note: This pump is intended for shallow well application only and is not intended to be used as a booster pump. It might be normal to hear a noise at the pressure tank when the pump is running, as water is flowing into the tank. If you are a resident of or want to locate a franchise in one of these states, we will not offer you a franchise unless and until we have complied with applicable pre-sale registration and disclosure requirements in your state. Remove the prime plug. Drummond location. The type of water pump you have for your well is either a jet pump or a submersible pump. Once the water is in the pressure tank, how does it know when to get more? I've adjusted cut on and off pressures, etc. Is your well running dry? The list above contains only some of the common issues homeowners might face in the future. Most liklely the well flow rate is very poor and your are pumping water out faster than the well recovers. This is usually a square or hexagonal-shaped plug located at the top of the pump. When you have a well for your homes water supply, your pressure tank will dictate the water pressure in your pipes. would water in the pump short it out so it will need to be replaced or can it easily be fixed. And then just stopped the next. Check valve in nosepiece needs to be cleaned out. Pull the contacts open and file off the burned and pitted areas using an ordinary nail file or emery board. Provincial and local laws may impact the services this independently owned and operated franchise location may perform at this time. replaced pump presure switch, worked ok but took awhile to pressurize but found out the 75 psi pop off valve was spewing water, when I forced the pop off valve closed it now blows breakers twice the amperage, from a 6amp to 10amp and blew a 15amp as well? (June 6, 2015) Ted said:water did not come on after electrical outage. Snap the new cover onto the old box (no need to rewire if you buy the same brand). This information is not intended as an offer to sell, or the solicitation of an offer to buy, a franchise. Or no water in the well, Hello there! We had a really bad storm in which the power kept going off. Continue reading below Our Video of the Day The Pump Starts Up to Much BenTrying a new starting capacitor is a reasonable effort but if you used the right value starting capacitor, the cap is properly wired and is itself un-damaged, and if you've checked out other "pump won't run" causes given, we're left guessing a loose or bad internal wiring connection in the start circuit or perhaps low supply voltage, On 2020-03-16 by BenG Extremely frustrated! Most, Verify that no GFI faults or outlets have been tripped. A clean funnel. When the diaphragm is old, wear and tear can prevent it from sensing the correct water pressure. When I try the manual restart the switch sparks and then I hear only a hum rather than the pump kicking on. Make sure all nuts and bolts get fastened. A simple cause for this can be a tripped circuit breaker, consequently shutting off the power of the pump. At this time there are no componets to the well pump. By knowing what pump issues cause which performance problems, you can begin pump repair or replacement more quickly. Be sure the discharge line is held down while you are doing this, as it can move around and cause serious injury or damage. The pressure tank and well pump should be wired on the same breaker, so if you find a label for well or water pump, that should be the power shut-off for the pressure tank, too. One thing that always gives me courage in attacking a question like this is that I figure someone has already had the problem and has come up with a solution. We are no longer supporting IE (Internet Explorer) as we strive to provide site experiences for browsers that support new web standards and security practices. Basically there are two problems. There can be several reasons for re-priming, one of the most common is evaporation of the fluid, and other reasons include leakage, pump movement and other maintenance related matters. The DC battery is charged from line voltage (until a power outage) but the power the unit produces from the DC battery is converted back to normal or standard AC power. Water pump would hum for approximately 30 seconds then stop. Switches are available in three different pressure ranges: 40 to 60 psi, 30 to 50 psi, and 20 to 40 psi. Make small adjustments to the pressure and check the pressure after each adjustment. While in the pump house I re-booted the power. Then run the pump, and it'll get rid of unwanted air. Here are some of the problems that can affect your well or well pump. This information will help you choose the best pipette controller to deliver the most accurate results for your intended applications. I can turn shaft with screw driver and get the same effect for 2-15 again, but like it said, even when it hums and shuts off and is completely silent, it gets hot. We also offer bearings, seals, gear oils, sprayer tips, nozzles, and pumps at each H.W. A shallow well jet pump's pressure switch regulates the amount time the pump motor runs.. . No cost EMI. Close off the valve that goes from the pressure tank to the plumbing of your house. The required lift is too high. When you notice flooding, call a plumber immediately. The most common cause of well pump failureis due to electrical problems. var s = document.getElementsByTagName('script')[0]; s.parentNode.insertBefore(po, s); 9 Common Well Pump Pressure Switch Problems, in Phoenix, AZ. 2. BenG, On 2020-03-11 - by (mod) - smoke came out of the motor. by (mod) A shallow well jet pump's pressure switch regulates the amount time the pump motor runs. Pat:Start at the electrical panel to confirm that the breaker or fuse is intact.Confirm power at the pump wall switchConfirm power at the pump pressure-control switchWatch out: opening any cover or box that exposes live electrical connections or wires risks death by electrocution if you are not familiar with and trained in safe practices. drummond shallow well pump problems. Watch out: for electrical shorts, fire hazards, shock hazrds - if a breaker keeps tripping, leave that circuit off until it's properly diagnosed and repaired. Intake line obstruction It should be between 20 and 30 pounds per square inch. (5) $228.00. Sorry Tom Sydor, I'm not sure what the question is. Find the prime plug (which is typically on the head of the pump).